Click HERE To Buy Now The DSC PC5108 Zone Expander is used to add additional hardwired zones to your existing control panel.  Each expander module has jumper settings that can be set for the desired zone numbers.  For example, if you are using an expander to add zones 9 through 16, you would make sure that jumper 1 is off...
There are several times people get confused on programming their zone definitions into the DSC security systems.  It is fairly easy to do, but can also be really confusing.  Zone definitions basically tells the system how that zone is to respond to that device being triggered.  In other words, the definition tells the system ...
A few people I've talked to in the past on the tech support line have a big misunderstanding of what Honeywell's RF House Code is used for or even what it is. Honeywell incorporated the RF House Code into the programming of quite a few of their panels whether they be the hardwired Vista panels equipped with wireless receivers...
Rather you are replacing or installing the WT4911Bat (battery) in the WT4911 outdoor wireless siren, you must follow certain directions.  Failure to follow instructions during this installation process may damage your battery and your siren may not work. When dealing with this certain type of battery, it must go through a dep...
As more and more homeowners are wanting to install their own system, they start to ask questions on what type of system to get. Most Do-It-Yourself people are wanting a wireless alarm system. Lets get one thing straight, no professional grade alarm system is completely wireless. What I mean by that is, you will have at least ...
Many people call and state that they have a trouble light or a triangle lit up on their keypad. If either of those are lit up, then your system is letting you know that something isn't right. Here is an easy way to tell what the trouble may be. On your DSC Keypad, hit " * 2 " Zone light will turn on showing trouble Zone Light...
We have had quite a few people calling in to ask whether the new Lynx Touch panels, the L5000 & L5100, will call out for self-monitoring purposes. Honeywell has been telling people that these panels will not do this. But we have tested this out here in the office and we do know for a fact that both of these panels will ca...
If you have already exhausted the power output of terminals 3 & 4 on your Vista control panel then you can use trigger output 17 on your Vista board to trigger 1 additional siren by doing the following. You will need the wiring harness used for this purpose. The part number is Honeywell 4120TR: Hook the negative of the s...
The DSC Power Series hardwire systems, like all systems have limits to their output used for sirens and strobes. You are limited to no more than 2 amps short-term draw with a good backup battery. Short term means during a reasonable alarm period. I’d recommend keeping your bell cutoff time to under 5 minutes to stay within th...