DSC PowerSeries NEO HS2LCDENGN Full Message LCD Hardwired Keypad with English function keys
This latest version with the "N" suffix is now compatible with both the DSC PowerSeries Neo and the PowerSeries Pro alarm panels.
PowerSeries NEO keypads have quite a few features that make them a great add-on to your NEO burglary detection system. Some of these features include five programmable keys for instant one-button activation of important NEO system functions. The keypads also feature a quick exit feature that alleviates the user's need to disarm and then rearm the system whenever they leave the building.
The HS2LCDENGN full message keypad is the newest in alpha-numeric readout keypads for the DSC NEO burglary systems. These keypads are what we recommend for a primary keypad because of the ability of this keypad to read out alpha and numeric characters on the screen. The 'ENG' model also displays English words instead of icons on the keypad function keys. Since the DSC system's programming is in alpha-numeric characters, this keypad will make your programming job ten times easier than using one of the ICN keypads to program with.
Specifications:
Dimensions:........ (L x W x D): 168mm x 122mm x 20 mm
(6 1/16" x 4 7/16" x 13/16")
LCD Viewable Area: .. 99 mm x 24 mm (3 9/10" x 15/16")
Current Draw: ............................................125 mA (Max)
HS2LCD/HS2LCDP/HS2ICN/HS2ICNP/
HS2LED............................................................100 mA
HS2LCDRF/HS2LCDRFP/HS2ICNRF/
HS2ICNRFP........................................................60 mA
Voltage: .................................................12 VDC Nominal
Operating Environment: ... -10°C to 55°C (14°F to 131°F)
Relative Humidity: ............................................. 5 to 93%
DSC HS2LCDENGN Installation manual
DSC HS2LCDENGN Quick manual
DSC HS2LCDENGN Specifications
QUESTIONS & ANSWERS
Ask a Question-
Will this keypad work with my existing hard wired sensors? I have 20 year old ADT hard wired sensors and I need to replace my old keypad. Thanks.
No, this keypad only works with the DSC Neo series. That's only been in production for the last 3 years or so.
-
I have an older DSC Power832 system and two of my three keypads have recently gone out, I was wondering if this was compatible with that system?
No this keypad is NOT compatible with the older DSC series. It only works with the newer Neo lineup. There are currently no keypads in production for the older discontinued panels.
Features
Menu programmingUp to 128 hardwired or wireless zones supported
Modern, slim-line landscape keypad
White backlit keys
Blue LCD display
5 programmable function keys
Input/Output terminal
Fire, medical and panic keys
Adjustable backlight and keypad buzzer
Dual wall-mount and front cover tamper
Available with English function keys
Related Products
-
{"id":10588585989,"title":"Alarm System Programming Service","handle":"alarm-system-programming-service","description":"\u003ch2\u003eAlarm System Programming Service\u003c\/h2\u003e\nAll of the systems we sell can be programmed by you. We even provide simplified quick start programming guides upon request for most systems to make it easier. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service. \u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Once ordered, \u003cspan data-mce-fragment=\"1\"\u003eyou will receive an emailed form to supply the required information.\u003c\/span\u003e This will delay shipping 2-3 days after we receive your pre-program form.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOur pre-programming service includes:\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eSetting up and enrolling sensors zones as desired (large systems beyond 16 zones may incur an additional charge)\u003c\/li\u003e\n\u003cli\u003eEnroll and program zone expanders, wireless transceivers, and power supply modules as needed\u003c\/li\u003e\n\u003cli\u003eCustom labeling alpha keypads\u003c\/li\u003e\n\u003cli\u003eSetting entry and exit delays\u003c\/li\u003e\n\u003cli\u003eSetting up user codes and authority levels\u003c\/li\u003e\n\u003cli\u003eTesting and verifying your system before shipping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVery large systems or those with custom \/ out-of-the-norm programming requirements such as those using multiple partitions may incur an additional fee. If you would like to verify if such a condition exists with your planned system, please feel to contact us. 95% of systems we program are A typical and do not incur additional fees to complete, so it is NOT common.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThis is a great way to get your system up and going right after you receive it. Just run the wire from the panel out to all of the devices, sirens, and keypads, power up the system, and rest easy that you are now protected.\u003cbr\u003e\u003cbr\u003eThis is good for those who aren't very technically inclined or for those that need it to function now and learn about the workings of their system later.\u003c\/p\u003e","published_at":"2017-10-26T13:47:36-04:00","created_at":"2017-10-26T12:49:59-04:00","vendor":"AlarmSystemStore.com","type":"Programming","tags":["DSC Alarm System Kits \u0026 Packages","DSC Alarm Systems","DSC Power 1616 Alarm Systems","DSC Power 1832 Alarm Systems","DSC Power 1864 Alarm Systems","DSC Power Series 1616","DSC Power Series 1832","DSC Power Series 1864","DSC PowerSeries NEO Kits \u0026 Packages","Els PW 20590","Hardwired Sensors","pre","pre-program","pre-programming","preprogram","preprogramming","pro"],"price":18995,"price_min":18995,"price_max":18995,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":53261795333,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PROGRAMMING","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Alarm System Programming Service","public_title":null,"options":["Default Title"],"price":18995,"weight":0,"compare_at_price":null,"inventory_quantity":-93,"inventory_management":null,"inventory_policy":"deny","barcode":"PROGRAMMING","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975","options":["Title"],"media":[{"alt":"Alarm System Programming Service - AlarmSystemStore.com","id":7363078226022,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003eAlarm System Programming Service\u003c\/h2\u003e\nAll of the systems we sell can be programmed by you. We even provide simplified quick start programming guides upon request for most systems to make it easier. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service. \u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Once ordered, \u003cspan data-mce-fragment=\"1\"\u003eyou will receive an emailed form to supply the required information.\u003c\/span\u003e This will delay shipping 2-3 days after we receive your pre-program form.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOur pre-programming service includes:\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eSetting up and enrolling sensors zones as desired (large systems beyond 16 zones may incur an additional charge)\u003c\/li\u003e\n\u003cli\u003eEnroll and program zone expanders, wireless transceivers, and power supply modules as needed\u003c\/li\u003e\n\u003cli\u003eCustom labeling alpha keypads\u003c\/li\u003e\n\u003cli\u003eSetting entry and exit delays\u003c\/li\u003e\n\u003cli\u003eSetting up user codes and authority levels\u003c\/li\u003e\n\u003cli\u003eTesting and verifying your system before shipping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVery large systems or those with custom \/ out-of-the-norm programming requirements such as those using multiple partitions may incur an additional fee. If you would like to verify if such a condition exists with your planned system, please feel to contact us. 95% of systems we program are A typical and do not incur additional fees to complete, so it is NOT common.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThis is a great way to get your system up and going right after you receive it. Just run the wire from the panel out to all of the devices, sirens, and keypads, power up the system, and rest easy that you are now protected.\u003cbr\u003e\u003cbr\u003eThis is good for those who aren't very technically inclined or for those that need it to function now and learn about the workings of their system later.\u003c\/p\u003e"}
-
{"id":10588585989,"title":"Alarm System Programming Service","handle":"alarm-system-programming-service","description":"\u003ch2\u003eAlarm System Programming Service\u003c\/h2\u003e\nAll of the systems we sell can be programmed by you. We even provide simplified quick start programming guides upon request for most systems to make it easier. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service. \u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Once ordered, \u003cspan data-mce-fragment=\"1\"\u003eyou will receive an emailed form to supply the required information.\u003c\/span\u003e This will delay shipping 2-3 days after we receive your pre-program form.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOur pre-programming service includes:\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eSetting up and enrolling sensors zones as desired (large systems beyond 16 zones may incur an additional charge)\u003c\/li\u003e\n\u003cli\u003eEnroll and program zone expanders, wireless transceivers, and power supply modules as needed\u003c\/li\u003e\n\u003cli\u003eCustom labeling alpha keypads\u003c\/li\u003e\n\u003cli\u003eSetting entry and exit delays\u003c\/li\u003e\n\u003cli\u003eSetting up user codes and authority levels\u003c\/li\u003e\n\u003cli\u003eTesting and verifying your system before shipping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVery large systems or those with custom \/ out-of-the-norm programming requirements such as those using multiple partitions may incur an additional fee. If you would like to verify if such a condition exists with your planned system, please feel to contact us. 95% of systems we program are A typical and do not incur additional fees to complete, so it is NOT common.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThis is a great way to get your system up and going right after you receive it. Just run the wire from the panel out to all of the devices, sirens, and keypads, power up the system, and rest easy that you are now protected.\u003cbr\u003e\u003cbr\u003eThis is good for those who aren't very technically inclined or for those that need it to function now and learn about the workings of their system later.\u003c\/p\u003e","published_at":"2017-10-26T13:47:36-04:00","created_at":"2017-10-26T12:49:59-04:00","vendor":"AlarmSystemStore.com","type":"Programming","tags":["DSC Alarm System Kits \u0026 Packages","DSC Alarm Systems","DSC Power 1616 Alarm Systems","DSC Power 1832 Alarm Systems","DSC Power 1864 Alarm Systems","DSC Power Series 1616","DSC Power Series 1832","DSC Power Series 1864","DSC PowerSeries NEO Kits \u0026 Packages","Els PW 20590","Hardwired Sensors","pre","pre-program","pre-programming","preprogram","preprogramming","pro"],"price":18995,"price_min":18995,"price_max":18995,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":53261795333,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PROGRAMMING","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Alarm System Programming Service","public_title":null,"options":["Default Title"],"price":18995,"weight":0,"compare_at_price":null,"inventory_quantity":-93,"inventory_management":null,"inventory_policy":"deny","barcode":"PROGRAMMING","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975","options":["Title"],"media":[{"alt":"Alarm System Programming Service - AlarmSystemStore.com","id":7363078226022,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/alarm-system-programming-service-562283.jpg?v=1595525975","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003eAlarm System Programming Service\u003c\/h2\u003e\nAll of the systems we sell can be programmed by you. We even provide simplified quick start programming guides upon request for most systems to make it easier. For those without the time or inclination to learn how to program them, we offer this optional pre-programming service. \u003cbr\u003e\u003cbr\u003eYou can have our technicians pre-program and setup your system prior to it shipping. Once ordered, \u003cspan data-mce-fragment=\"1\"\u003eyou will receive an emailed form to supply the required information.\u003c\/span\u003e This will delay shipping 2-3 days after we receive your pre-program form.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOur pre-programming service includes:\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eSetting up and enrolling sensors zones as desired (large systems beyond 16 zones may incur an additional charge)\u003c\/li\u003e\n\u003cli\u003eEnroll and program zone expanders, wireless transceivers, and power supply modules as needed\u003c\/li\u003e\n\u003cli\u003eCustom labeling alpha keypads\u003c\/li\u003e\n\u003cli\u003eSetting entry and exit delays\u003c\/li\u003e\n\u003cli\u003eSetting up user codes and authority levels\u003c\/li\u003e\n\u003cli\u003eTesting and verifying your system before shipping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVery large systems or those with custom \/ out-of-the-norm programming requirements such as those using multiple partitions may incur an additional fee. If you would like to verify if such a condition exists with your planned system, please feel to contact us. 95% of systems we program are A typical and do not incur additional fees to complete, so it is NOT common.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThis is a great way to get your system up and going right after you receive it. Just run the wire from the panel out to all of the devices, sirens, and keypads, power up the system, and rest easy that you are now protected.\u003cbr\u003e\u003cbr\u003eThis is good for those who aren't very technically inclined or for those that need it to function now and learn about the workings of their system later.\u003c\/p\u003e"}
-
{"id":7795348869,"title":"DSC HS3251CP01 PowerSeries Neo Kit","handle":"dsc-hs3251cp01-powerseries-neo-kit","description":"\u003cp class=\"product-excerpt\"\u003eThe HS3251 kit provides you with everything you need to get started on a hardwired DSC NEO setup. You'll get an HS2032 NEO, as well as a programmable keypad, the HS2LCDENGN. If you would like a wireless NEO setup, the \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs32119cp01-kit\" title=\"DSC NEO HS32119CP01 kit\"\u003eHS32119 kit\u003c\/a\u003e is where you should start.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eDSC HS3251CP01 PowerSeries Neo Kit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eWhat you get:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlarm cabinet\u003cem\u003e\u003cbr\u003e\u003c\/em\u003eHS2032 control board\u003cbr\u003e16.5V 40VA Transformer\u003cbr\u003e12V 7A Backup Battery\u003cbr\u003eHS2LCDENG Keypad\u003cbr\u003eSD15W 15 Watt Indoor Dual Tone Siren\u003cbr\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-system-programming-service\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePurchase Optional Pre-programming for your system HERE\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe DSC PowerSeries NEO is the newest in DSC's line up. What you'll get with the HS3251CP01 kit are the DSC NEO HS2032 control board and PC5003C cabinet. This also comes with the PTC1640 transformer and a 12 volt 7 amp backup battery. You'll also get the HS2LCDENG Full message keypad, which will allow easier programming and the ability to label zones. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis is a hardwired\/wireless hybrid system. It comes with 8 hardwired zones on the mainboard, and you can add more hardwired zones by installing the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2108-8-hardwired-zone-expander-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2108 8-Hardwired Zone Expander Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. As we just mentioned, the DSC NEO can use wireless devices as well. The DSC NEO wireless devices can be used if you have a wired keypad with a built-in transceiver such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-neo-hs2lcdrf9eng-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRF9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e or by using the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-hsm2host9-powerg-915mhz-host-transceiver-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2HOST9 Transceiver Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. The wireless range that the NEO has is an impressive half-mile, and the device's lithium batteries will last a good 6-8 years before having to be replaced because of the energy-saving features that the NEO has to offer. You'll get a total of 32 zones with the HS2032 panel in any combination of hardwired and wireless devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 board has 2 PGM outputs, which can be used for additional attached devices such as smoke detectors. The PGMs can also be used as triggers to set off additional notifiers like add-on chimes when certain system events occur. You can expand up to 38 PGMs using modules such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2204-high-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2204\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e and the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2208-low-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2208\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e PGM expander cards. The HSM2204 is a high-current output and power supply. It adds 4 PGM outputs. The HSM2208 is a standard 8 PGM output expansion board. Those with the 2 onboard PGM outputs bring the PGM output total to 38.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Because of the keypad you get with this kit, the \u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdeng-full-message-lcd-hardwired-keypad\" target=\"_blank\"\u003eHS2LCDENG\u003c\/a\u003e; you'll\u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e have a much better time programming your new NEO panel. This keypad will read out all programming information and has a 32 character display. DSC has made programming a little easier with the NEO as they've combined a lot of the programming sections that they previously separated in the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-power-1616-alarm-systems\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePC1616\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e, PC1832, and PC1864 panels. All sections and toggle options are labeled, so you're not guessing where you're at in programming. You also can scroll through sections using the arrow keys on the keypad.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eAnother feature that the DSC NEO boasts is a 500 event log. If you need to know what alarms have happened in the recent past, then you'll be able to pull them up from the event log as long as you have one of the full message keypads. You'll be able to pinpoint which sensor was activated and when. For instance, if you go on vacation and have an event when you're gone, then you can see it in the log.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 can store up to 72 user codes. These codes are used for daily use to arm and disarm the system. This is more than what most people need for a home installation as far as user codes go, but these systems can also be used in a small business setting for companies with a plethora of employees. You can also add a proximity capable keypad such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdrfp9eng-lcd-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRFP9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e so you can use the NEO proximity tags. This makes arming and disarming simple as users have to swipe their tags across the keypad to arm or disarm the system. You can add 71 prox tags to the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis version of the HS2032NK is CP01 compliant and has all the fail-safes to help protect against false alarms. You will not be able to pick values for some programming sections below a certain value, such as the entry\/exit delays.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064_HS2128_V1-13_IG_Eng_R003.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/PS-Neo_HS2016-32-64-128_v1-0_Reference-Manual__Extended_R001_en.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064-HS2128_V1-3_UM_R001_NA.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/30001878_HS2_Control_Panel_Spec_w_Alarm-com_en_draft2_cs.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2017-05-10T12:05:06-04:00","created_at":"2017-05-10T12:07:06-04:00","vendor":"DSC","type":"DSC PowerSeries NEO Kits \u0026 Packages","tags":["DSC PowerSeries NEO","DSC PowerSeries NEO Kits \u0026 Packages"],"price":25295,"price_min":25295,"price_max":25295,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29165494981,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DSC-HS3251CP01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"DSC HS3251CP01 PowerSeries Neo Kit","public_title":null,"options":["Default Title"],"price":25295,"weight":5897,"compare_at_price":null,"inventory_quantity":4,"inventory_management":"shopify","inventory_policy":"continue","barcode":"DSC-HS3251CP01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-750878.jpg?v=1595525945","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-672251.jpg?v=1595525945","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-438788.jpg?v=1595525945"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901","options":["Title"],"media":[{"alt":null,"id":20749863911526,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901","width":1024},{"alt":"DSC HS3251CP01 PowerSeries Neo Kit - AlarmSystemStore.com","id":7363067936870,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-750878.jpg?v=1595525945"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-750878.jpg?v=1595525945","width":1024},{"alt":"DSC HS3251CP01 PowerSeries Neo Kit - AlarmSystemStore.com","id":7363067969638,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-672251.jpg?v=1595525945"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-672251.jpg?v=1595525945","width":1024},{"alt":"DSC HS3251CP01 PowerSeries Neo Kit - AlarmSystemStore.com","id":7363068002406,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-438788.jpg?v=1595525945"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-438788.jpg?v=1595525945","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp class=\"product-excerpt\"\u003eThe HS3251 kit provides you with everything you need to get started on a hardwired DSC NEO setup. You'll get an HS2032 NEO, as well as a programmable keypad, the HS2LCDENGN. If you would like a wireless NEO setup, the \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs32119cp01-kit\" title=\"DSC NEO HS32119CP01 kit\"\u003eHS32119 kit\u003c\/a\u003e is where you should start.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eDSC HS3251CP01 PowerSeries Neo Kit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eWhat you get:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlarm cabinet\u003cem\u003e\u003cbr\u003e\u003c\/em\u003eHS2032 control board\u003cbr\u003e16.5V 40VA Transformer\u003cbr\u003e12V 7A Backup Battery\u003cbr\u003eHS2LCDENG Keypad\u003cbr\u003eSD15W 15 Watt Indoor Dual Tone Siren\u003cbr\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-system-programming-service\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePurchase Optional Pre-programming for your system HERE\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe DSC PowerSeries NEO is the newest in DSC's line up. What you'll get with the HS3251CP01 kit are the DSC NEO HS2032 control board and PC5003C cabinet. This also comes with the PTC1640 transformer and a 12 volt 7 amp backup battery. You'll also get the HS2LCDENG Full message keypad, which will allow easier programming and the ability to label zones. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis is a hardwired\/wireless hybrid system. It comes with 8 hardwired zones on the mainboard, and you can add more hardwired zones by installing the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2108-8-hardwired-zone-expander-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2108 8-Hardwired Zone Expander Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. As we just mentioned, the DSC NEO can use wireless devices as well. The DSC NEO wireless devices can be used if you have a wired keypad with a built-in transceiver such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-neo-hs2lcdrf9eng-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRF9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e or by using the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-hsm2host9-powerg-915mhz-host-transceiver-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2HOST9 Transceiver Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. The wireless range that the NEO has is an impressive half-mile, and the device's lithium batteries will last a good 6-8 years before having to be replaced because of the energy-saving features that the NEO has to offer. You'll get a total of 32 zones with the HS2032 panel in any combination of hardwired and wireless devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 board has 2 PGM outputs, which can be used for additional attached devices such as smoke detectors. The PGMs can also be used as triggers to set off additional notifiers like add-on chimes when certain system events occur. You can expand up to 38 PGMs using modules such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2204-high-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2204\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e and the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2208-low-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2208\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e PGM expander cards. The HSM2204 is a high-current output and power supply. It adds 4 PGM outputs. The HSM2208 is a standard 8 PGM output expansion board. Those with the 2 onboard PGM outputs bring the PGM output total to 38.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Because of the keypad you get with this kit, the \u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdeng-full-message-lcd-hardwired-keypad\" target=\"_blank\"\u003eHS2LCDENG\u003c\/a\u003e; you'll\u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e have a much better time programming your new NEO panel. This keypad will read out all programming information and has a 32 character display. DSC has made programming a little easier with the NEO as they've combined a lot of the programming sections that they previously separated in the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-power-1616-alarm-systems\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePC1616\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e, PC1832, and PC1864 panels. All sections and toggle options are labeled, so you're not guessing where you're at in programming. You also can scroll through sections using the arrow keys on the keypad.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eAnother feature that the DSC NEO boasts is a 500 event log. If you need to know what alarms have happened in the recent past, then you'll be able to pull them up from the event log as long as you have one of the full message keypads. You'll be able to pinpoint which sensor was activated and when. For instance, if you go on vacation and have an event when you're gone, then you can see it in the log.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 can store up to 72 user codes. These codes are used for daily use to arm and disarm the system. This is more than what most people need for a home installation as far as user codes go, but these systems can also be used in a small business setting for companies with a plethora of employees. You can also add a proximity capable keypad such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdrfp9eng-lcd-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRFP9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e so you can use the NEO proximity tags. This makes arming and disarming simple as users have to swipe their tags across the keypad to arm or disarm the system. You can add 71 prox tags to the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis version of the HS2032NK is CP01 compliant and has all the fail-safes to help protect against false alarms. You will not be able to pick values for some programming sections below a certain value, such as the entry\/exit delays.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064_HS2128_V1-13_IG_Eng_R003.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/PS-Neo_HS2016-32-64-128_v1-0_Reference-Manual__Extended_R001_en.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064-HS2128_V1-3_UM_R001_NA.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/30001878_HS2_Control_Panel_Spec_w_Alarm-com_en_draft2_cs.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
-
{"id":7795348869,"title":"DSC HS3251CP01 PowerSeries Neo Kit","handle":"dsc-hs3251cp01-powerseries-neo-kit","description":"\u003cp class=\"product-excerpt\"\u003eThe HS3251 kit provides you with everything you need to get started on a hardwired DSC NEO setup. You'll get an HS2032 NEO, as well as a programmable keypad, the HS2LCDENGN. If you would like a wireless NEO setup, the \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs32119cp01-kit\" title=\"DSC NEO HS32119CP01 kit\"\u003eHS32119 kit\u003c\/a\u003e is where you should start.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eDSC HS3251CP01 PowerSeries Neo Kit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eWhat you get:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlarm cabinet\u003cem\u003e\u003cbr\u003e\u003c\/em\u003eHS2032 control board\u003cbr\u003e16.5V 40VA Transformer\u003cbr\u003e12V 7A Backup Battery\u003cbr\u003eHS2LCDENG Keypad\u003cbr\u003eSD15W 15 Watt Indoor Dual Tone Siren\u003cbr\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-system-programming-service\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePurchase Optional Pre-programming for your system HERE\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe DSC PowerSeries NEO is the newest in DSC's line up. What you'll get with the HS3251CP01 kit are the DSC NEO HS2032 control board and PC5003C cabinet. This also comes with the PTC1640 transformer and a 12 volt 7 amp backup battery. You'll also get the HS2LCDENG Full message keypad, which will allow easier programming and the ability to label zones. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis is a hardwired\/wireless hybrid system. It comes with 8 hardwired zones on the mainboard, and you can add more hardwired zones by installing the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2108-8-hardwired-zone-expander-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2108 8-Hardwired Zone Expander Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. As we just mentioned, the DSC NEO can use wireless devices as well. The DSC NEO wireless devices can be used if you have a wired keypad with a built-in transceiver such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-neo-hs2lcdrf9eng-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRF9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e or by using the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-hsm2host9-powerg-915mhz-host-transceiver-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2HOST9 Transceiver Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. The wireless range that the NEO has is an impressive half-mile, and the device's lithium batteries will last a good 6-8 years before having to be replaced because of the energy-saving features that the NEO has to offer. You'll get a total of 32 zones with the HS2032 panel in any combination of hardwired and wireless devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 board has 2 PGM outputs, which can be used for additional attached devices such as smoke detectors. The PGMs can also be used as triggers to set off additional notifiers like add-on chimes when certain system events occur. You can expand up to 38 PGMs using modules such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2204-high-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2204\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e and the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2208-low-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2208\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e PGM expander cards. The HSM2204 is a high-current output and power supply. It adds 4 PGM outputs. The HSM2208 is a standard 8 PGM output expansion board. Those with the 2 onboard PGM outputs bring the PGM output total to 38.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Because of the keypad you get with this kit, the \u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdeng-full-message-lcd-hardwired-keypad\" target=\"_blank\"\u003eHS2LCDENG\u003c\/a\u003e; you'll\u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e have a much better time programming your new NEO panel. This keypad will read out all programming information and has a 32 character display. DSC has made programming a little easier with the NEO as they've combined a lot of the programming sections that they previously separated in the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-power-1616-alarm-systems\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePC1616\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e, PC1832, and PC1864 panels. All sections and toggle options are labeled, so you're not guessing where you're at in programming. You also can scroll through sections using the arrow keys on the keypad.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eAnother feature that the DSC NEO boasts is a 500 event log. If you need to know what alarms have happened in the recent past, then you'll be able to pull them up from the event log as long as you have one of the full message keypads. You'll be able to pinpoint which sensor was activated and when. For instance, if you go on vacation and have an event when you're gone, then you can see it in the log.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 can store up to 72 user codes. These codes are used for daily use to arm and disarm the system. This is more than what most people need for a home installation as far as user codes go, but these systems can also be used in a small business setting for companies with a plethora of employees. You can also add a proximity capable keypad such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdrfp9eng-lcd-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRFP9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e so you can use the NEO proximity tags. This makes arming and disarming simple as users have to swipe their tags across the keypad to arm or disarm the system. You can add 71 prox tags to the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis version of the HS2032NK is CP01 compliant and has all the fail-safes to help protect against false alarms. You will not be able to pick values for some programming sections below a certain value, such as the entry\/exit delays.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064_HS2128_V1-13_IG_Eng_R003.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/PS-Neo_HS2016-32-64-128_v1-0_Reference-Manual__Extended_R001_en.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064-HS2128_V1-3_UM_R001_NA.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/30001878_HS2_Control_Panel_Spec_w_Alarm-com_en_draft2_cs.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2017-05-10T12:05:06-04:00","created_at":"2017-05-10T12:07:06-04:00","vendor":"DSC","type":"DSC PowerSeries NEO Kits \u0026 Packages","tags":["DSC PowerSeries NEO","DSC PowerSeries NEO Kits \u0026 Packages"],"price":25295,"price_min":25295,"price_max":25295,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":29165494981,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DSC-HS3251CP01","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"DSC HS3251CP01 PowerSeries Neo Kit","public_title":null,"options":["Default Title"],"price":25295,"weight":5897,"compare_at_price":null,"inventory_quantity":4,"inventory_management":"shopify","inventory_policy":"continue","barcode":"DSC-HS3251CP01","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-750878.jpg?v=1595525945","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-672251.jpg?v=1595525945","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-438788.jpg?v=1595525945"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901","options":["Title"],"media":[{"alt":null,"id":20749863911526,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hskit32-51cp01nt-power-2032-alarm-system-kit.jpg?v=1635263901","width":1024},{"alt":"DSC HS3251CP01 PowerSeries Neo Kit - AlarmSystemStore.com","id":7363067936870,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-750878.jpg?v=1595525945"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-750878.jpg?v=1595525945","width":1024},{"alt":"DSC HS3251CP01 PowerSeries Neo Kit - AlarmSystemStore.com","id":7363067969638,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-672251.jpg?v=1595525945"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-672251.jpg?v=1595525945","width":1024},{"alt":"DSC HS3251CP01 PowerSeries Neo Kit - AlarmSystemStore.com","id":7363068002406,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-438788.jpg?v=1595525945"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-hs3251cp01-powerseries-neo-kit-438788.jpg?v=1595525945","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp class=\"product-excerpt\"\u003eThe HS3251 kit provides you with everything you need to get started on a hardwired DSC NEO setup. You'll get an HS2032 NEO, as well as a programmable keypad, the HS2LCDENGN. If you would like a wireless NEO setup, the \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs32119cp01-kit\" title=\"DSC NEO HS32119CP01 kit\"\u003eHS32119 kit\u003c\/a\u003e is where you should start.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eDSC HS3251CP01 PowerSeries Neo Kit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eWhat you get:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlarm cabinet\u003cem\u003e\u003cbr\u003e\u003c\/em\u003eHS2032 control board\u003cbr\u003e16.5V 40VA Transformer\u003cbr\u003e12V 7A Backup Battery\u003cbr\u003eHS2LCDENG Keypad\u003cbr\u003eSD15W 15 Watt Indoor Dual Tone Siren\u003cbr\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-system-programming-service\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePurchase Optional Pre-programming for your system HERE\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe DSC PowerSeries NEO is the newest in DSC's line up. What you'll get with the HS3251CP01 kit are the DSC NEO HS2032 control board and PC5003C cabinet. This also comes with the PTC1640 transformer and a 12 volt 7 amp backup battery. You'll also get the HS2LCDENG Full message keypad, which will allow easier programming and the ability to label zones. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis is a hardwired\/wireless hybrid system. It comes with 8 hardwired zones on the mainboard, and you can add more hardwired zones by installing the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2108-8-hardwired-zone-expander-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2108 8-Hardwired Zone Expander Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. As we just mentioned, the DSC NEO can use wireless devices as well. The DSC NEO wireless devices can be used if you have a wired keypad with a built-in transceiver such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-neo-hs2lcdrf9eng-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRF9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e or by using the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-hsm2host9-powerg-915mhz-host-transceiver-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2HOST9 Transceiver Module\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e. The wireless range that the NEO has is an impressive half-mile, and the device's lithium batteries will last a good 6-8 years before having to be replaced because of the energy-saving features that the NEO has to offer. You'll get a total of 32 zones with the HS2032 panel in any combination of hardwired and wireless devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 board has 2 PGM outputs, which can be used for additional attached devices such as smoke detectors. The PGMs can also be used as triggers to set off additional notifiers like add-on chimes when certain system events occur. You can expand up to 38 PGMs using modules such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2204-high-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2204\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e and the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hsm2208-low-current-output-module\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHSM2208\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e PGM expander cards. The HSM2204 is a high-current output and power supply. It adds 4 PGM outputs. The HSM2208 is a standard 8 PGM output expansion board. Those with the 2 onboard PGM outputs bring the PGM output total to 38.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Because of the keypad you get with this kit, the \u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdeng-full-message-lcd-hardwired-keypad\" target=\"_blank\"\u003eHS2LCDENG\u003c\/a\u003e; you'll\u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003e have a much better time programming your new NEO panel. This keypad will read out all programming information and has a 32 character display. DSC has made programming a little easier with the NEO as they've combined a lot of the programming sections that they previously separated in the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-power-1616-alarm-systems\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003ePC1616\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e, PC1832, and PC1864 panels. All sections and toggle options are labeled, so you're not guessing where you're at in programming. You also can scroll through sections using the arrow keys on the keypad.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eAnother feature that the DSC NEO boasts is a 500 event log. If you need to know what alarms have happened in the recent past, then you'll be able to pull them up from the event log as long as you have one of the full message keypads. You'll be able to pinpoint which sensor was activated and when. For instance, if you go on vacation and have an event when you're gone, then you can see it in the log.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe HS2032 can store up to 72 user codes. These codes are used for daily use to arm and disarm the system. This is more than what most people need for a home installation as far as user codes go, but these systems can also be used in a small business setting for companies with a plethora of employees. You can also add a proximity capable keypad such as the \u003c\/span\u003e\u003ca class=\"editor-rtfLink\" href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-hs2lcdrfp9eng-lcd-keypad\" target=\"_blank\"\u003e\u003cspan data-preserver-spaces=\"true\"\u003eHS2LCDRFP9ENG\u003c\/span\u003e\u003c\/a\u003e\u003cspan data-preserver-spaces=\"true\"\u003e so you can use the NEO proximity tags. This makes arming and disarming simple as users have to swipe their tags across the keypad to arm or disarm the system. You can add 71 prox tags to the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThis version of the HS2032NK is CP01 compliant and has all the fail-safes to help protect against false alarms. You will not be able to pick values for some programming sections below a certain value, such as the entry\/exit delays.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064_HS2128_V1-13_IG_Eng_R003.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Installation Manual\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/PS-Neo_HS2016-32-64-128_v1-0_Reference-Manual__Extended_R001_en.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Reference Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/HS2016-HS2032-HS2064-HS2128_V1-3_UM_R001_NA.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\" target=\"_blank\"\u003e\u003cspan\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 User Manual\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/30001878_HS2_Control_Panel_Spec_w_Alarm-com_en_draft2_cs.pdf?18331804550319602332\" title=\"DSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\" target=\"_blank\"\u003eDSC NEO HS2016, HS2032, HS2064, HS2128 Specifications Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
-
{"id":1577275621478,"title":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series","handle":"dsc-le2080r-at-cellular-at-t-lte-communicator-for-dsc-neo-series","description":"\u003ch2\u003eDSC LE2080R-AT Cellular AT\u0026amp;T LTE Communicator For DSC Neo Series\u003c\/h2\u003e\nThe DSC LE2080R-AT is a cellular only cellular communicator that can be used to send alarm signals from your \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-powerseries-neo\" title=\"DSC PowerSeries NEO\"\u003eDSC NEO\u003c\/a\u003e system to a central station monitoring service. \u003cbr\u003e\u003cbr\u003eThis cellular communicator sends alarm signals over the AT\u0026amp;T 4G LTE network which will get your alarms to the central station lightning fast. The LE2080R-AT uses 128-bit AES encryption to ensure that any signals sent from your DSC NEO alarm system can't be intercepted or tampered with. The LE2080R-AT also features a supervised heartbeat which allows for monitoring the operating status of the cellular communicator. \u003cbr\u003e\u003cbr\u003eThis will connect to your DSC NEO via an included PCLink cable. It measures 5.875\" W x 4.5\" H and installs inside the main cabinet. The included antenna protrudes out of your alarm cabinet's knock out the hole. You can also mount this cellular communicator remotely by using a \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-pcl422-communicator-remote-mounting-module\" title=\"DSC PowerSeries NEO PCL422 Communicator Remote Mounting Module\"\u003ePCL-422\u003c\/a\u003e remote mounting module. The LE2080R-AT also has onboard LED status lights which will allow you to check signal strength and troubleshoot errors if any issues arise.\u003cbr\u003e\u003cbr\u003eTo use this communicator with our central station monitoring service you will need to purchase the following two items:\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-monitoring\" title=\"Alarm monitoring service for one year\"\u003eAlarm monitoring service for one year\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/gsm-ip-monitoring-add-on\" title=\"GSM\/IP Monitoring Add-on\"\u003eGSM\/IP Monitoring Add-on\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eIf you want Alarm.com services then you will need a different communicator for your DSC NEO and those can be found \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/alarm-com-communicators\" title=\"Alarm.com Communicators\"\u003eHERE\u003c\/a\u003e.\u003cbr id=\"tinymce\" class=\"mce-content-body\" data-id=\"product-description\" style=\"overflow-y: auto; padding-left: 0px; padding-right: 0px; padding-bottom: 0px;\" role=\"textbox\" aria-label=\"Description\" aria-multiline=\"true\" contenteditable=\"true\"\u003e\u003chr\u003eBack up and primary Cellular alarm communication\u003cbr\u003eSupervision heartbeats via Cellular\u003cbr\u003e128-bit AES encryption via Cellular\u003cbr\u003eFull event reporting using SIA or Contact ID protocol\u003cbr\u003eSIM Card (included)\u003cbr\u003eRemote activating and programming through C24 Communications\u003cbr\u003eUL standard \u0026amp; encrypted line security\u003cbr\u003eULC passive or active line security levels\u003cbr\u003eAntenna Extension Kits available: LT-15ANT, LT-25ANT, LT-50ANT\u003cbr\u003eSignal strength and trouble display\u003cbr\u003ePC-Link connection\u003cbr\u003eVisual verification over Cellular\u003cbr\u003eThe communicator can be housed in a separate cabinet using PCL-422 Communicator Remote Mounting Module\u003cbr\u003eR model supports 3rd party integration option via RS232 serial connection","published_at":"2018-11-20T12:57:07-05:00","created_at":"2018-11-20T09:53:57-05:00","vendor":"DSC","type":"DSC PowerSeries NEO Accessories \u0026 Expansion","tags":["4G","DSC PowerSeries NEO","DSC PowerSeries NEO Accessories \u0026 Expansion","Els PW 22653","GSM","LE2080R","LE2080R-AT","LTE","PCL-422"],"price":26995,"price_min":26995,"price_max":26995,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":15551627755622,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DSC-LE2080R-AT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series","public_title":null,"options":["Default Title"],"price":26995,"weight":1134,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"DSC-LE2080R-AT","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-951023.jpg?v=1601445696","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-129261.jpg?v=1601445696","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-128860.jpg?v=1601445696","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-529533.jpg?v=1601445696"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695","options":["Title"],"media":[{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436324966,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436357734,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-951023.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-951023.jpg?v=1601445696","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436390502,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-129261.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-129261.jpg?v=1601445696","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436423270,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-128860.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-128860.jpg?v=1601445696","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436456038,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-529533.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-529533.jpg?v=1601445696","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003eDSC LE2080R-AT Cellular AT\u0026amp;T LTE Communicator For DSC Neo Series\u003c\/h2\u003e\nThe DSC LE2080R-AT is a cellular only cellular communicator that can be used to send alarm signals from your \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-powerseries-neo\" title=\"DSC PowerSeries NEO\"\u003eDSC NEO\u003c\/a\u003e system to a central station monitoring service. \u003cbr\u003e\u003cbr\u003eThis cellular communicator sends alarm signals over the AT\u0026amp;T 4G LTE network which will get your alarms to the central station lightning fast. The LE2080R-AT uses 128-bit AES encryption to ensure that any signals sent from your DSC NEO alarm system can't be intercepted or tampered with. The LE2080R-AT also features a supervised heartbeat which allows for monitoring the operating status of the cellular communicator. \u003cbr\u003e\u003cbr\u003eThis will connect to your DSC NEO via an included PCLink cable. It measures 5.875\" W x 4.5\" H and installs inside the main cabinet. The included antenna protrudes out of your alarm cabinet's knock out the hole. You can also mount this cellular communicator remotely by using a \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-pcl422-communicator-remote-mounting-module\" title=\"DSC PowerSeries NEO PCL422 Communicator Remote Mounting Module\"\u003ePCL-422\u003c\/a\u003e remote mounting module. The LE2080R-AT also has onboard LED status lights which will allow you to check signal strength and troubleshoot errors if any issues arise.\u003cbr\u003e\u003cbr\u003eTo use this communicator with our central station monitoring service you will need to purchase the following two items:\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-monitoring\" title=\"Alarm monitoring service for one year\"\u003eAlarm monitoring service for one year\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/gsm-ip-monitoring-add-on\" title=\"GSM\/IP Monitoring Add-on\"\u003eGSM\/IP Monitoring Add-on\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eIf you want Alarm.com services then you will need a different communicator for your DSC NEO and those can be found \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/alarm-com-communicators\" title=\"Alarm.com Communicators\"\u003eHERE\u003c\/a\u003e.\u003cbr id=\"tinymce\" class=\"mce-content-body\" data-id=\"product-description\" style=\"overflow-y: auto; padding-left: 0px; padding-right: 0px; padding-bottom: 0px;\" role=\"textbox\" aria-label=\"Description\" aria-multiline=\"true\" contenteditable=\"true\"\u003e\u003chr\u003eBack up and primary Cellular alarm communication\u003cbr\u003eSupervision heartbeats via Cellular\u003cbr\u003e128-bit AES encryption via Cellular\u003cbr\u003eFull event reporting using SIA or Contact ID protocol\u003cbr\u003eSIM Card (included)\u003cbr\u003eRemote activating and programming through C24 Communications\u003cbr\u003eUL standard \u0026amp; encrypted line security\u003cbr\u003eULC passive or active line security levels\u003cbr\u003eAntenna Extension Kits available: LT-15ANT, LT-25ANT, LT-50ANT\u003cbr\u003eSignal strength and trouble display\u003cbr\u003ePC-Link connection\u003cbr\u003eVisual verification over Cellular\u003cbr\u003eThe communicator can be housed in a separate cabinet using PCL-422 Communicator Remote Mounting Module\u003cbr\u003eR model supports 3rd party integration option via RS232 serial connection"}
-
{"id":1577275621478,"title":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series","handle":"dsc-le2080r-at-cellular-at-t-lte-communicator-for-dsc-neo-series","description":"\u003ch2\u003eDSC LE2080R-AT Cellular AT\u0026amp;T LTE Communicator For DSC Neo Series\u003c\/h2\u003e\nThe DSC LE2080R-AT is a cellular only cellular communicator that can be used to send alarm signals from your \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-powerseries-neo\" title=\"DSC PowerSeries NEO\"\u003eDSC NEO\u003c\/a\u003e system to a central station monitoring service. \u003cbr\u003e\u003cbr\u003eThis cellular communicator sends alarm signals over the AT\u0026amp;T 4G LTE network which will get your alarms to the central station lightning fast. The LE2080R-AT uses 128-bit AES encryption to ensure that any signals sent from your DSC NEO alarm system can't be intercepted or tampered with. The LE2080R-AT also features a supervised heartbeat which allows for monitoring the operating status of the cellular communicator. \u003cbr\u003e\u003cbr\u003eThis will connect to your DSC NEO via an included PCLink cable. It measures 5.875\" W x 4.5\" H and installs inside the main cabinet. The included antenna protrudes out of your alarm cabinet's knock out the hole. You can also mount this cellular communicator remotely by using a \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-pcl422-communicator-remote-mounting-module\" title=\"DSC PowerSeries NEO PCL422 Communicator Remote Mounting Module\"\u003ePCL-422\u003c\/a\u003e remote mounting module. The LE2080R-AT also has onboard LED status lights which will allow you to check signal strength and troubleshoot errors if any issues arise.\u003cbr\u003e\u003cbr\u003eTo use this communicator with our central station monitoring service you will need to purchase the following two items:\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-monitoring\" title=\"Alarm monitoring service for one year\"\u003eAlarm monitoring service for one year\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/gsm-ip-monitoring-add-on\" title=\"GSM\/IP Monitoring Add-on\"\u003eGSM\/IP Monitoring Add-on\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eIf you want Alarm.com services then you will need a different communicator for your DSC NEO and those can be found \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/alarm-com-communicators\" title=\"Alarm.com Communicators\"\u003eHERE\u003c\/a\u003e.\u003cbr id=\"tinymce\" class=\"mce-content-body\" data-id=\"product-description\" style=\"overflow-y: auto; padding-left: 0px; padding-right: 0px; padding-bottom: 0px;\" role=\"textbox\" aria-label=\"Description\" aria-multiline=\"true\" contenteditable=\"true\"\u003e\u003chr\u003eBack up and primary Cellular alarm communication\u003cbr\u003eSupervision heartbeats via Cellular\u003cbr\u003e128-bit AES encryption via Cellular\u003cbr\u003eFull event reporting using SIA or Contact ID protocol\u003cbr\u003eSIM Card (included)\u003cbr\u003eRemote activating and programming through C24 Communications\u003cbr\u003eUL standard \u0026amp; encrypted line security\u003cbr\u003eULC passive or active line security levels\u003cbr\u003eAntenna Extension Kits available: LT-15ANT, LT-25ANT, LT-50ANT\u003cbr\u003eSignal strength and trouble display\u003cbr\u003ePC-Link connection\u003cbr\u003eVisual verification over Cellular\u003cbr\u003eThe communicator can be housed in a separate cabinet using PCL-422 Communicator Remote Mounting Module\u003cbr\u003eR model supports 3rd party integration option via RS232 serial connection","published_at":"2018-11-20T12:57:07-05:00","created_at":"2018-11-20T09:53:57-05:00","vendor":"DSC","type":"DSC PowerSeries NEO Accessories \u0026 Expansion","tags":["4G","DSC PowerSeries NEO","DSC PowerSeries NEO Accessories \u0026 Expansion","Els PW 22653","GSM","LE2080R","LE2080R-AT","LTE","PCL-422"],"price":26995,"price_min":26995,"price_max":26995,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":15551627755622,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DSC-LE2080R-AT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series","public_title":null,"options":["Default Title"],"price":26995,"weight":1134,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"DSC-LE2080R-AT","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-951023.jpg?v=1601445696","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-129261.jpg?v=1601445696","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-128860.jpg?v=1601445696","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-529533.jpg?v=1601445696"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695","options":["Title"],"media":[{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436324966,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-297786.jpg?v=1601445695","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436357734,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-951023.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-951023.jpg?v=1601445696","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436390502,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-129261.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-129261.jpg?v=1601445696","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436423270,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-128860.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-128860.jpg?v=1601445696","width":1024},{"alt":"DSC LE2080R-AT Cellular AT\u0026T LTE Communicator For DSC Neo Series - AlarmSystemStore.com","id":7743436456038,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-529533.jpg?v=1601445696"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/dsc-le2080r-at-cellular-att-lte-communicator-for-dsc-neo-series-529533.jpg?v=1601445696","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003eDSC LE2080R-AT Cellular AT\u0026amp;T LTE Communicator For DSC Neo Series\u003c\/h2\u003e\nThe DSC LE2080R-AT is a cellular only cellular communicator that can be used to send alarm signals from your \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/dsc-powerseries-neo\" title=\"DSC PowerSeries NEO\"\u003eDSC NEO\u003c\/a\u003e system to a central station monitoring service. \u003cbr\u003e\u003cbr\u003eThis cellular communicator sends alarm signals over the AT\u0026amp;T 4G LTE network which will get your alarms to the central station lightning fast. The LE2080R-AT uses 128-bit AES encryption to ensure that any signals sent from your DSC NEO alarm system can't be intercepted or tampered with. The LE2080R-AT also features a supervised heartbeat which allows for monitoring the operating status of the cellular communicator. \u003cbr\u003e\u003cbr\u003eThis will connect to your DSC NEO via an included PCLink cable. It measures 5.875\" W x 4.5\" H and installs inside the main cabinet. The included antenna protrudes out of your alarm cabinet's knock out the hole. You can also mount this cellular communicator remotely by using a \u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/dsc-powerseries-neo-pcl422-communicator-remote-mounting-module\" title=\"DSC PowerSeries NEO PCL422 Communicator Remote Mounting Module\"\u003ePCL-422\u003c\/a\u003e remote mounting module. The LE2080R-AT also has onboard LED status lights which will allow you to check signal strength and troubleshoot errors if any issues arise.\u003cbr\u003e\u003cbr\u003eTo use this communicator with our central station monitoring service you will need to purchase the following two items:\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/alarm-monitoring\" title=\"Alarm monitoring service for one year\"\u003eAlarm monitoring service for one year\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.alarmsystemstore.com\/products\/gsm-ip-monitoring-add-on\" title=\"GSM\/IP Monitoring Add-on\"\u003eGSM\/IP Monitoring Add-on\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eIf you want Alarm.com services then you will need a different communicator for your DSC NEO and those can be found \u003ca href=\"https:\/\/www.alarmsystemstore.com\/collections\/alarm-com-communicators\" title=\"Alarm.com Communicators\"\u003eHERE\u003c\/a\u003e.\u003cbr id=\"tinymce\" class=\"mce-content-body\" data-id=\"product-description\" style=\"overflow-y: auto; padding-left: 0px; padding-right: 0px; padding-bottom: 0px;\" role=\"textbox\" aria-label=\"Description\" aria-multiline=\"true\" contenteditable=\"true\"\u003e\u003chr\u003eBack up and primary Cellular alarm communication\u003cbr\u003eSupervision heartbeats via Cellular\u003cbr\u003e128-bit AES encryption via Cellular\u003cbr\u003eFull event reporting using SIA or Contact ID protocol\u003cbr\u003eSIM Card (included)\u003cbr\u003eRemote activating and programming through C24 Communications\u003cbr\u003eUL standard \u0026amp; encrypted line security\u003cbr\u003eULC passive or active line security levels\u003cbr\u003eAntenna Extension Kits available: LT-15ANT, LT-25ANT, LT-50ANT\u003cbr\u003eSignal strength and trouble display\u003cbr\u003ePC-Link connection\u003cbr\u003eVisual verification over Cellular\u003cbr\u003eThe communicator can be housed in a separate cabinet using PCL-422 Communicator Remote Mounting Module\u003cbr\u003eR model supports 3rd party integration option via RS232 serial connection"}