Silent Knight SK4 4 zone Fire Alarm Control Panel

Quick Overview
Silent Knight SK4 4 zone Fire Alarm Control Panel The SIL-SK4 is a 4 zone Fire Alarm Control Panel that is compatible with devices such as two or four wire...

Available : In Stock

$367.95

Ship out same day or within 24 hours
Add to Wishlist

Silent Knight SK4 4 zone Fire Alarm Control Panel

The SIL-SK4 is a 4 zone Fire Alarm Control Panel that is compatible with devices such as two or four wire smoke detectors pull stations or any other normally open contacts.

Upon activation of any compatible smoke detector or any normally-open compatible fire device; the panel can activate strobes, light up an LED to alert you, sound the sounder at the panel, and also activate a communications device to notify a remote monitoring station. This panel is also compatible with the new System Sensor i3 devices which have many features to help keep your system operating smoothly.

It also features NAC protocol which means that sounders can be silenced, but the strobes will still function and this all through the use of a single pair of wires.

Specifications:

SK-4 Primary AC: 120 VAC @ 50/60 Hz, 2.3A
Wiring: 14 AWG (2.0 mm2) with 600 V insulation min


Initiating Device Circuits (IDCs)
Operating Voltage: 22 VDC nominal; power-limited
Standby Current: 4 mA
Alarm Current: 15 mA min
Short-circuit Current: 40 mA max
Loop Resistance: 100 ohm max
EOL Resistor: 4.7K ohm, 1/2 watt


NACs
Signaling Current: 2.5A @ 24 VDC with standard transformer or 5A total (2.5A per NAC) with additional optional transformer, power-limited
EOL Resistor: 4.7K ohm, 1/2 watt


Form C Relays
Types: Trouble, alarm, and supervisory
Contact Ratings: 2A@ 30 VAC, resistive


Auxiliary Output
Resettable and non-resettable
Operating Voltage: 24 VDC nominal
Current: 500 mA max, power-limited; total current for non-resettable power, resettable power and two NACs must not exceed 6.0A (requires additional transformer)

Features

  • Four Style B (Class B) initiating device circuits (IDCs)
  • Two Style Y (Class B) notification appliance circuit (NAC)
  • Optional module converts all IDCs and NACs to Class A (PN SK-CAC4)
  • Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72
  • Selectable for System Sensor, Wheelock, and Gentex protocols
  • Selective silence feature allows manual silence of horns while strobes continue to flash on the same NAC
  • Program for combination tamper supervisory monitor and waterflow alarm on one zone
  • Silent or audible walk test operation mode
  • Alarm verification selectable per zone
  • Program each zone for supervisory or fire with separate red and yellow LEDs
  • Disable switches provided per zone
  • Program NACS for
  • Silence inhibit
  • Auto silence
  • Strobe synchronization
  • Temporal or steady signal
  • Silenceable or non-silenceable Disable
  • Form C alarm, trouble, and supervisory relays
  • 3A total usable current
  • 6A total usable current with optional second transformer (PN SK-TRM24 or SK-TRM24E)
  • Optional dress panel (PN SK-DP2/4)