Silent Knight SK2 2 zone Fire Alarm Control Panel

The SIL-SK2 is a 2 zone Fire Alarm Control Panel that is compatible with devices such as two or four wire smoke detectors pull stations or any other normally open contacts.

Upon activation of any compatible smoke detector or any normally-open compatible fire device; the panel can activate strobes, light up an LED to alert you, sound the sounder at the panel, and also activate a communications device to notify a remote monitoring station. This panel is also compatible with the new System Sensor i3 devices which have many features to help keep your system operating smoothly.

It also features NAC protocol which means that sounders can be silenced, but the strobes will still function and this all through the use of a single pair of wires.

Specifications:

SK-2 Primary AC: 120 VAC @ 50/60 Hz, 2.3A
SK-2E Primary AC: 240 VAC @ 50 Hz, 1.15A
Wiring: 14 AWG (2.0 mm2) with 600 V insulation min
Initiating Device Circuits (IDCs)
Operating Voltage: 22 VDC nominal; power-limited
Standby Current: 4 mA
Alarm Current: 15 mA min
Short-circuit Current: 40 mA max
Loop Resistance: 100' max
EOL Resistor: 4.7K ohm, 1/2 watt
NACs
2.5A @ 24 VDC with standard transformer, power-limited
Signaling Current: 2.5A max with standard transformer
EOL Resistor: 4.7K ohm, 1/2 watt
Form C Relays
Types: Trouble and alarm
Contact Ratings: 2A @ 30 VAC, resistive
Auxiliary Output
Resettable
Operating Voltage: 24 VDC nominal
Current: 500 mA max, power-limited

Features

  • Two Style B (Class B) initiating device circuits (IDCs)
  • One Style Y (Class B) notification appliance circuit (NAC)
  • Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72
  • Selectable for System Sensor, Wheelock, and Gentex protocols
  • Selective silence feature allows manual silence of horns while strobes continue to flash on the same NAC
  • Silent or audible walk test operation mode
  • Alarm verification selectable per zone
  • Program each zone for supervisory or fire with separate red and yellow LEDs
  • Disable switches provided per zone
  • Program NACS for
  • Silence inhibit
  • Auto silence
  • Strobe synchronization
  • Temporal or steady signal
  • Silenceable or non-silenceable Disable
  • Form C alarm and trouble relays
  • 3A total usable current
  • Optional dress panel (PN SK-DP2/4)