Home > Fire Alarm Systems > Silent Knight Commercial Fire Alarm Systems >

Silent Knight 5495 power supply module
Silent Knight 5495 power supply module

Alternative Views:

Our Price: $346.95

Availability: IN STOCK: Ships out same day or within 24 hours
Product Code: SIL-5495


Silent Knight 5495 power supply module

The SIL-5495 is a 6 amp power supply module that provides its own AC power and charging circuit for batteries. It also has its own back up battery.

The 5495 can provide supervision functions as well in the following cases:

• Low AC power
• Low battery condition
• Earth ground fault
• Auxiliary output power limit
• EOL supervision trouble or
power limited condition at an

Whenever a trouble condition occurs this unit will then, in turn, create a trouble condition on the main panel that it is connected to. The 5495 also contains a Form C relay output for trouble conditions as an alternative to the notification of circuit trouble that the unit already has.


Electrical Specification
AC input: 120 VAC at 2 amps
Output: 24 VDC at 6 amps
Standby 75 mA
Alarm 205 mA
power circuit: 1
circuits: 4
configuration: 2 Class A (Style Z) 4 Class B (Style Y) (1 Class A & 2 Class B)
Amps per output circuit: 3.0 (6.0 amps total)
Notification circuit output: 20.4 to 27.3 VDC @ 3.0 amps each, 4.7 kW EOL resistor required on each Class B circuit
No. of inputs 2
Input configuration: 2 Class B or 2 Class A Input
voltage range: 9 - 32 VDC
Battery charging capacity: 35.0 AH
Ambient temp.: 32° to 120° F (0° to 49° C)

Dimensions: 12.25” W x 16” H x
3” D (30.88 cm W
x 40.64 cm H x
7.62 D cm)

Indicator Lights
AC power on : Green
Battery trouble: Yellow
Ground fault: Yellow
Aux trouble: Yellow
Output troubles (1-4): Yellow

  • • UL Listed for 6 amps of notification power
    • Power supply’s advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems
    • Dip switches allow for easy reconfiguration
    • 24 VDC filtered output voltage
    • Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B
    • Additional continuous auxiliary output
    • 3 amps per output circuit
    • 2 inputs; 2 Class B or 2 Class A
    • Ground fault detector/indicator
    • Independent trouble relay
    • AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders
    • Built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday
    • Stand alone operation
    • Lightweight design adds to ease of installation and reduces shipping costs
    • Operates with most polarized, UL Listed notification devices
    • ANSI Cadence pattern output capability built-in

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Fire Alarm Systems > Silent Knight Commercial Fire Alarm Systems